14

VEGAPULS 56 Profibus PA

2 Types and versions

VEGAPULS 56 sensors are a newly devel-
oped generation of very compact, high tem-
perature radar sensors. They enable for the
first time non-contact level measurements
under high temperatures and pressures.
They offer the advantages of radar level
measurement for applications in which the
special advantages of radar could not be
previously applied due to extreme process
conditions.

VEGAPULS 56 radar sensors utilise two-wire
technology perfectly. The supply voltage and
the output signal are transmitted via one two-
wire cable. They provide an analogue
4 … 20 mA output signal as output or meas-
uring signal. This operating instructions
manual describes the sensors with digital
output signal.

Types and versions

VEGAPULS 56
DN 150

VEGAPULS 56
DN 80 pipe antenna

VEGAPULS 56
DN 50 pipe antenna

2.1 Type survey

General features

• Level measurement of processes and

products under high temperatures and
high pressures

• Measuring range 0 … 20 m
• Ex approved in Zone 1 and Zone 10 (IEC)

or Zone 0 and Zone 20 (ATEX) classifica-
tion mark EEx ia IIC T6 or
EEx d ia IIC T6

• Integrated measured value display
• External measured value display which can

be mounted at a distance of up to
25 m in Ex area

Survey of features

Signal output
- digital transmission of measuring signals to

a VEGAMET signal conditioning instrument
or the VEGALOG processing system

Power supply
– two-wire technology (voltage supply and

digital signal via one two-wire cable)

Process fitting
– DN 50; ANSI 2“
– DN 80; ANSI 3“
– DN 100; ANSI 4“
– DN 150; ANSI 6“
– DN 200; ANSI 8“
– DN 250; ANSI 10“

Adjustment
– P C
– adjustment module in the sensor
– adjustment module in external indicating

instrument

Antennas
– horn antenna with stainless steel horn and

ceramic tip

– standpipe antenna only with ceramic tip or

with small horn and ceramic tip