VEGA VEGAPULS 56 Profibus PA User Manual
Page 79
VEGAPULS 56 Profibus PA
79
PN 16
PN 25
PN 40
PN 64
bar
40
25
16
-40
0
50
100
150
200
250
300
350
˚C
64
Flange DIN DN 50
Material: 1.4571
Groove and tongue acc.
to DIN 2512 Form F, N
bar
40
25
16
-40
0
50
100
150
200
250
300
350
˚C
PN 16
PN 25
PN 40
Flange DIN DN 50
Material: 1.4571
Seal surface acc. to DIN
2526 Form B, C, D, E
Technical data
Ambient conditions
Ambient temperature on the housing
-20°C … +60°C
Flange temperature
(process temperature)
-40°C … +350°C (pressure-dependent), see
following diagrams
Vessel insulation
in process temperatures exceeding 200°C, the
rear of the flange must be covered with a heat
insulation, see also chapter "4 Mounting and
installation“.
Storage and transport temperature
-40°C … +80°C
Protection
IP 66/IP 67
Protection class
- two-wire sensor
II
- four-wire sensor
I
Overvoltage category
III
Vessel pressure
max. 64 bar (temperature-dependent), see
following diagrams
Burst pressure
- at 20°C
> 400 bar
- at 350°C
> 250 bar