VEGA VEGAPULS 56 Profibus PA User Manual
Page 54
54
VEGAPULS 56 Profibus PA
Setup
• Save the adjustments with "
OK
OK
OK
OK
OK“ and you
are again in the menu window "
Meas. envi-
ronment“.
Meas. environment/Meas. conditions
• Click in the menu window "
Meas. environ-
Meas. environ-
Meas. environ-
Meas. environ-
Meas. environ-
ment
ment
ment
ment
ment“ to "Meas. condition
Meas. condition
Meas. condition
Meas. condition
Meas. condition“.
• In the menu window "
Meas. conditions“ you
click on the options corresponding to your
application.
• Confirm with """""
OK
OK
OK
OK
OK“““““.
After a few seconds, during which the adjust-
ments are permanently saved in the sensor,
you are again in the window "
Meas. environ-
ment“.
Meas. conditions/Pulse velocity
In the menu item "
Pulse velocity“, adjustments
are only necessary when measuring in a
surge or bypass tube (standpipe). When
measuring in a standpipe, a shift of the run-
ning time of the radar signal is caused which
is dependent on the inner diameter of the
standpipe. To take this running time shift into
account, it is necessary to inform the sensor
in this menu about the diameter (inner) of the
standpipe.
• With "
OK
OK
OK
OK
OK“ you save the adjustments in the
sensor.
• Click in the window "
Meas. environment“ to
"
Quit
Quit
Quit
Quit
Quit“.