VEGAPULS 56 Profibus PA
Technical data
Flange DIN DN 250
Material: 1.4571
Groove and tongue acc.
to DIN 2512 Form F, N
PN 16
PN 25
PN 40
PN 64
bar
40
25
16
64
-40
0
50
100
150
200
250
300
350
˚C
PN 16
PN 25
PN 40
bar
40
25
16
-40
0
50
100
150
200
250
300
350
˚C
Flange DIN DN 250
Material: 1.4571
Seal surface acc. to DIN
2526 Form B, C, D, E
Flanges acc. to ANSI (ASA) B16.5 seal surface RF, material 1.4571 in sizes 2“ to 10“ can be
used along the entire temperature range of -40°C … 350°C with the appropriate nominal
pressures from 150 lbs, 300 lbs, 600 lbs and 900 lbs.
Other flanges and appropriate process data on request.
Connection cables
Two-wire sensors
power supply and signal via one two-wire
cable
Electrical connection
- cable entry
for Aluminium and plastic housing:
one cable entry (four-wire: two- cable entries)
and spring-loaded terminal connection
up to max. 2.5 mm
2
wire cross-section.
- plug connection
optional for plastic housing:
four-pole, polarity reversal-safe screw
connection (four-wire: two plug connections)
Cable entry
- ia terminal compartment
1 … 2 x M20 x 1.5 (cable ø 5 … 9 mm)
Ground connection
max. 4 mm
2