2 measurement of liquids, Heat insulation, Sensor on din socket piece – VEGA VEGAPULS 56 Profibus PA User Manual

Page 24: Mounting and installation

Advertising
background image

24

VEGAPULS 56 Profibus PA

0

2,4 m

3,8 m

2,4 m

3,8 m

10 m

0 m

20 m

14˚

22˚

50 %

100 %

Heat insulation

Mounting on longer DIN socket piece

> 10 mm

Emission cone of a DN 250 horn antenna

Meas. distance

Mounting and installation

Heat insulation

In process temperatures of more than 200°C
the rear of the flange must be insulated to
protect the sensor electronics from radiated
heat.

We recommend integrating the sensor insula-
tion into the vessel insulation and extending it
approx. up to the first tube segment.

3.2 Measurement of liquids

Sensor on DIN socket piece

Most commonly, the mounting of radar sen-
sors is done on short DIN socket pieces. The
lower side of the instrument flange is the
reference plane for the measuring range. The
antenna should always protrude out of the
flange pipe.

Mounting on DIN socket piece

Reference plane

With a longer DIN socket piece, the horn
antenna must protrude at least 10 mm out of
the socket.

When mounting on dished vessel tops, the
antenna must also protrude at least 10 mm
beyond the longer side of the socket).

40°C

60°C

100°C

240°C

350°C

Vessel insulation

max. 350°C

emitted power

emitted power