VEGA VEGASON 51P…53P Profibus PA User Manual

Page 18

Advertising
background image

18

VEGASON 51P … 53P

Technical data

Ambient conditions

Ambient temperature on the housing

-40°C … +80°C

Process temperature (transducer)

-40°C … +80°C (StEx: -20°C … +75°C)

Storage and transport temperature

-40°C … +80°C

Vessel pressure
- VEGASON 51, 52

-0.4 … 2.0 bar (absolute 3 bar)

- VEGASON 53

-0.4 … 1.5 bar (absolute 2.5 bar)

Protection
- sensor

IP 67

- transducer, process

IP 68

Protection class

II

Overvoltage category

III

Self-heating at 40°C
ambient temperature to
- sensor

45°C

- transducer, process

55°C

Ex technical data

Comprehensive data included in the attached approval documents (yellow binder)
Classification ia

intrinsically safe

Classification mark

II 1G EEx ia IIC T6 or II 2G EEx ia IIC T6

Ex approved

Zone 0, Zone 1 (ATEX)
Zone 0, Zone 1 (CENELEC, PTB, IEC)

Permissible ambient temperature
on the housing
- T6

-40°C … +42°C

- T5

-40°C … +58°C

- T4, T3

-40°C … +60°C

Permissible ambient temperature
on the transducer when used
in Ex areas
- T6

45°C

- T5

60°C

- T4

60°C

- T3

60°C

Process connections

VEGASON 51

G1

1

/

2

A, 1

1

/

2

“ NPT

VEGASON 52

G 2 A, 2“ NPT

VEGASON 52

DN 100 compression flange or mounting loop

Connection cables

Power supply

supply and signal via one two-wire cable

Electrical connection

spring terminals (max. 2.5 mm

2

)

Cable entry

2 x M20 x 1.5 (cable diameter 5 … 9 mm)
or 2 x

1

/

2

“ NPT (cable diameter

3.6 … 8.7 mm or 0.12 … 0.34 inch)

Ground connection

max. 4 mm

2

Advertising