Parabolic effects of rounded or arched vessel tops, Socket piece too long, Mounting and installation – VEGA VEGASON 51P…53P Profibus PA User Manual

Page 34

Advertising
background image

34

VEGASON 51P … 53P

Mounting and installation

Correct and wrong length of socket piece

Wrong

Correct

Reference plane

³ 60 mm

Wrong

Mounting on a vessel with parabolic tank top

Correct

~

1

/

2

vessel
radius

Wrong

³ 60 mm

Parabolic effects of rounded or arched
vessel tops

Round or parabolic tank tops act like a para-
bolic mirror on the signals. If the sensor is
placed at the focal point of such a parabolic
tank top, the sensor receives amplified false
echoes. The optimum location is generally in
the area of half the vessel radius from the
centre.

Socket piece too long

If the sensor is mounted in a socket exten-
sion that is too long, strong false echoes are
caused, and measurement is hindered. Make
sure that the transducer protrudes at least
30 mm out of the socket piece.

Advertising