2 operation – VEGA VEGASON 71 - D User Manual

Page 13

Advertising
background image

VEGASON 71 - D

13

3 Operating surface

1. Indication

of mea-
sured
values

2. Mode

range

3. Parameter

adjustment

3.2

Operation

VEGASON 71 - D has 3 modes which can be enquired with the MOD-button (scrolling)
-

indication of measured values

-

mode range

-

parameter adjustment.

After 60 mins. VEGASON 71 - D resets automatically to mode "Indication of measured values".

MOD

MOD

+

-

MOD

STO

+

-

5.000

0 00

0 99

48.94

0 - 00

– – – –

0

1. Indication of measured value

Flow in m

3

/h

Flow in %
Level in %
Distance in m

2. Mode range

Enquiry of the mode numbers in the MODEFIELD. The
parameters of the enquired mode numbers can be
checked or modified in mode 3.

3. Parameter adjustment

Programming of the parameters in the PARAMETER
FIELD. The parameter of the respectively enquired
mode can be modified and stored with the key STO.
Push the MOD-key if no modification is desired or if the
modified parameter should not be stored. In both cases
reset in mode 1.

In mode 99 the mode range of the general parameter adjustment can be quit and the optimization as well as the
linearization curve 4 … 6 can be enquired. Reset also in mode 99.

If after STO the actual mode range is enquired again within 60 mins., the last enquired mode number appears
automatically.

Cursor position

Figures raise

Figures lower

Cursor position

Figures raise

Figures lower