6 Flow measurement

6

Flow measurement

6.1

Linearization

6.1.1 Meter flume / weir

The system measures the level and calculates the flow.

The relationship between level and flow is linear in most
cases.

The level value (in %) must be therefore converted into a
flow porportional value.

The necessary mathematical functions depend on the
flumes and weirs used.

For the standard flumes and weirs the respective functions
are available as pre-programmed linearization curves and
can be directly enquired.

Flumes / weirs which do not correspond to the known
functions, can be imitated via three programmable
linearization curves.

NO standard flumes /
weirs

Programmable
linearization curves

Enquire mode range

0 - 99

=

4

5

6

Program index markers
for linearization curves

4 - 01

32

5 - 01

32

6 - 01

32

Enquire linearization
curves

0 - 18

=

4

5

6

Standard flumes / weirs

Pre-programmed
linearization curves

Enquire linearization
curves

0 - 18

=

1

7

bis

12

Processing results flow proportional