2 Technical Information

2.2

Technical data, VEGASON 71 - D

Power supply

Operating voltage
- Standard

U

nenn

= 24 V AC (16 … 42 V), 50/60 Hz

U

nenn

= 24 V DC (16 … 60 V)

- Option

U

nenn

= 230 V AC (90 … 250 V), 50/60 Hz

Power consumption at U

nenn

and max-load

12 VA, 5 W

Fuse for version
16 … 42 V AC or 16 … 60 V DC

2 A

90 … 250 V AC

500 mA

Measuring range

Min. distance

0.300 m

Max. distance

4.000 m (5.000 m)

Measuring data

Min. span

10 cm

Display in

m (0.000 … 5.000 distance)

Resolution in

mm

Scanning

3 mm

Measuring frequency

50 kHz

Measuring rate

0,4 sec.

Angle of reflection (at –3 dB)

8

°

Linearity error after empty and full adjustment

< 0,1 % of measuring range

Temperature error of the electronics

0,1 % / 10 k of measuring range

Central electronics

Inputs

1 (1 channel, for 1 sensor)

Outputs

see section "output"

Housing material

Polycarbonate

Electrical connection

max. 1,5 mm

2

Cable entry

1 x Pg 7, 1 x Pg 13,5 (up to max. 5 x Pg 13,5)

Protection

IP 65

Ambient temperature

-20

°

C … +60

°

C

Storage and transport temperature

-20

°

C … +80

°

C

Weight

approx. 1,9 kg

Output

Indication

LC-display

2, 4-digit each

Flow module

1 flow relay output

active, with status indication (LED)

- voltage impulse

24 V

- current impulse

20 mA

- pulse duration

200 ms

1 sampling relay output

floating spdt, with status indication (LED)

- contact material

AgCdO and Au plated

- min.

turn-on voltage

10 mV

switching current

10

µ

A

- max.

turn-on voltage

250 V AC, 60 V DC

switching current

2 A AC, 1 A DC

- max.

breaking capacity

125 VA, 60 W