7.6.3 Rectangular weir without throat

With sharp weir edge (without throat)

Weir edge
K = 6593

Calculation of the actual flow value (Q)

The following formula can be used for calculation of the
actual flow for liquid levels < h

max

… > h

min

.

Q = B • K • h

1,5

Q in m

3

/h

B in m
h in m

Assumed values for a calculation example
B =

0,4 m

K =

6593

h =

0,13 m

Calculation example
Q =

0,4 • 6593• 0,13

1,5

= 123,61 m

3

/h

Programming acc. to calculation example
Q

max

= 123,61 m

3

/h

-

Mode

0 - 82

, flow = 0124

-

Mode

0 - 83

, multiplier = 0

-

Mode

0 - 84

, time unit = 3

7 Output results

3 - 4 x h

max

2 - 3 x h

max

B

45

°

Selection of the actual flow (Q)

Flow schedule for usual rectangular weir

B

Q

max

h

max

Q

min

h

min

in mm in m

3

/h

in mm

in m

3

/h

in mm

200

54,81

120

19,4

60

400

310,0

240

38,7

60

600

650,0

300

58,1

60

800

1592,0

450

77,5

60

1000

3064,0

600

96,9

60

1500

6423,0

750

145,3

60

If a rectangular weir acc. to above value is used, the value
for Q

max

can be taken out of the respective column and can

be used for programming of mode

0 - 82

0 - 84

.

Programming acc. to selection Q

max

= 1592 m

3

/h

- Mode

0 - 82

, flow = 1592

- Mode

0 - 83

, multiplier = 0

- Mode

0 - 84

, time unit = 3

Explanation:
Q

max

= max. flow in m

3

/h

B

= weir width in mm or m

K

= throat specific factor for above rectangular weir = 6593

h

max

= max. weir height in mm or m

k

= thickness of the weir in mm

k

3 mm

h

max

k

3 mm

or