B

7 Output results

7.6.1 Khafagi-Venturi flume

with rectangular cross-section and flat bottom

Selection of the actual flow (Q)

Flow schedule for usual Venturi flumes

B

K

Q

max

h

max

Q

min

h

min

in mm (Factor)

in m

3

/h

in mm

in m

3

/h

in mm

45

605

80

260

4,8

40

120

838

124

280

9,3

50

160

1106

210

330

16,2

60

200

1383

363

410

25,6

70

240

1654

532

470

37,4

80

320

2178

864

540

58,8

90

640

4280

3776

920

383

200

If a Venturi flume acc. to above value is used, the value for
Q

max

can be taken out of the respective column and can be

used for programming of mode

0 - 82

0 - 84

.

Programming acc. to selection Q

max

= 864 m

3

/h

- Mode

0 - 82

, flow = 0864

- Mode

0 - 83

, multiplier = 0

- Mode

0 - 84

, time unit = 3 (h)

Calculation of the actual flow value (Q)

The following formula can be used for calculation of the
actual flow for liquid levels < h

max

… > h

min

.

Q = K • h

1,5

Q in m

3

/h

B in m
h in m

Assumed values for a calculation example
B = 0,16 m
K = 1106 (derived from B)
h = 0,25 m

Calculation example
Q =

1106 • 0,25

1,5

= 138,2 m

3

/h

Programming acc. to calculation example
Q

max

= 138,2 m

3

/h

-

Mode

0 - 82

, flow = 0138

-

Mode

0 - 83

, multiplier = 0

-

Mode

0 - 84

, time unit = 3 (h)

90

°

h

max

Sensor

3 - 4 x h

max

Sensor

Explanation:
Q

max

= max. flow in m

3

/h

B

= flume width in mm or m

K

= flume specific factor

h

max

= max. damming height in mm or m

K (factor)