General installation instructions

Open flume with weir (e.g. rectangular)

-

Installation of the transducer upstream

-

Observe distance to the weir (3 … 4 x h

max

)

-

Installation if possible centered to the flume

-

Installation vertical to the surface of the flow product

-

Observe min. distance relating to h

max

-

Min. distance diaphragm opening to downstream water

5 cm

90

°

h

max

Sensor

Sensor

3 - 4 x h

max

2 x h

max

h

max

3 - 4 x h

max

90

°

upstream water

Min.-

distance

5 cm

90

°

Open flume with measuring channel (e.g. Khafagi-Venturi flume)

-

Installation of the sensor at the inlet

-

Observe distance to the Khafagi-Venturi flume (3 … 4 x h

max

)

-

Installation if possible centered to the flume

-

Installation vertically to the surface of the flow product

-

Min. distance relating to the height of damping h

max

Note
Otherwise follow the installation guidelines given by the channel manufacturer.