VEGA VEGASON 71 - D User Manual

Page 16

Advertising
background image

VEGASON 71 - D

16

4.2

Mode range, general parameter adjustment (continuation)

Function

Mode-no.

Mode description

Parameter

Page

(bold = factory settings)

(level

0 - 58

Coordination

module)

- measuring result in m ........................................

1

- measuring result in % ........................................

2

2

2

2

2

0 - 59

not coordinated ......................................................

– – – –

P. 32

Switching command

0 - 60

- on ......................................................................

0.000

m …

5.000

m

0 - 61

- off ......................................................................

0.000

m …

5.000

m

0 - 62

64

not coordinated ......................................................

– – – –

Current

Characteristics

module

0 - 65

- end ....................................................................

20.00

20.00

20.00

20.00

20.00

00.00

P. 33

0 - 66

- begin .................................................................

00.00

04.00

04.00

04.00

04.00

04.00

20.00

0 - 67

81

not coordinated ......................................................

– – – –

Max.

0 - 82

Flow (max. 4 positions) ..........................................

0001

9999

1000

1000

1000

1000

1000

flow

0 - 83

Multiplier

(at level

- flow x 1 ..............................................................

0

0

0

0

0

100 %)

- flow x 10 ............................................................

1

- flow x 100 ..........................................................

2

P. 24

- flow x 1000 ........................................................

3

0 - 84

Time unit for above flow
- seconds .............................................................

1

11

11

- minutes ..............................................................

2

- hours .................................................................

3

Flow
module
Pulse value

0 - 85

Flow quantity / impulse ..........................................

0001

9999

1000

1000

1000

1000

1000

for flow

0 - 86

Multiplier

relay

- flow quantity / impulse x 1 .................................

0

0

0

0

0

P. 24

- flow quantity / impulse x 10 ...............................

1

- flow quantity / impulse x 100 .............................

2

- flow quantity / impulse x 1000 ...........................

3

Pulse value

0 - 87

Flow quantity / impulse ..........................................

0001

9999

1000

1000

1000

1000

1000

for samp-

0 - 88

Multiplier

ling relay

- flow quantity / impulse x 1 .................................

0

- flow quantity / impulse x 10 ...............................

1

11

11

- flow quantity / impulse x 100 .............................

2

P. 25

- flow quantity / impulse x 1000 ...........................

3

- flow quantity / impulse x 10000 .........................

4

- flow quantity / impulse x 100000 .......................

5

- flow quantity / impulse x 1000000 .....................

6

0 - 89

Time dependent controls in hours .........................

0

0

0

0

0

(off) …

100

0 - 90

Min. flow volume limit in % .....................................

0.0

0.0

0.0

0.0

0.0

100

P. 25

0 - 91

u.

92

not coordinated ......................................................

– – – –

4 Set-up

Relay
output 2

Current out-
put 1 + 2

Advertising