See following diagrams – VEGA VEGAFLEX 82 4 … 20 mA_HART two-wire Rod and cable probe With SIL qualification User Manual

Page 80

Advertising
background image

80

12 Supplement

VEGAFLEX 82 • 4 … 20 mA/HART two-wire

44222-EN-130823

Ʋ Medium

Bulk solids - cereals, flour, cement (dielectric con-

stant ~2.0)

Ʋ Installation

Probe end does not touch the vessel bottom

Sensor parameter adjustment

No gating out of false signals carried out

Typical deviation

5)

See following diagrams

L

0

-2 mm

(-0.079

")

2 mm

(0.079

")

15 mm

(0.591

"

)

-10 mm

(-0.394

")

0,3 m

(11.811

"

)

0,08 m

(3.15

"

)

0,02 m

(0.787

")

1

Fig. 48: Deviation VEGAFLEX 82 in rod version
1 Dead band - no measurement possible in this area

L Probe length

0

2 mm

(0.079

")

-2 mm

(-0.079

")

15 mm

(0.591

")

10 mm

(0.394

")

0,08 m

(3.15

")

0,3 m

(11.811

")

0,1 m

(3.94

")

L

1

Fig. 49: Deviation VEGAFLEX 82 in cable version in water
1 Dead band - no measurement possible in this area

L Probe length

Repeatability

≤ ±1 mm

Specification for safety accuracy (SIL)

Siehe Safety Manual

Variables influencing measurement accuracy
Specifications for the digital measured value

5)

Depending on the installation conditions, there can be deviations which can be rectified with an adaptation of

the adjustment or a change of the measured value offset in the DTM service mode