Chapter 7: Roof Assembly

Installing the 6–Hole Intermediate Purlins

Intermediate purlins must be installed to connect each A-frame roof rafter assembly together. The inter-
mediate purlins at 11.6 ft radius (near the center collar) and 19.4 ft radius (second from the center collar)
connecting each A-frame roof rafter assembly are unique than the other intermediate purlins installed at
other diameters of the roof.

Before You Begin
All A-frame roof rafter assemblies must be installed and secured to both the center collar and the eave
brackets.

1. Install the intermediate purlin (A) to the purlin clips (B and D) located outside of each A-frame roof

rafter assembly (E).

2. Install six flange bolts (C) and six flange nuts (F) to each end of the purlin (A) securing the intermedi-

ate purlin to the purlin clips.

3. Tighten the hardware to the recommended torque specifications. See

Bolt Torque Specifications,

page 24

.

Figure 7-28 Exploded view of the 6–hole intermediate purlin

A

Purlin (CTR-0213)

D

Left Purlin clip (CTR-0099)

B

Right Purlin clip (CTR-0100)

E

A-frame roof assembly

C

1/2 x 1-3/4 in. flange bolt (S-10252)

F

1/2 in. flange nut (S-10253)

After You Finish
Repeat this procedure only for the remaining 6–hole intermediate purlins (near the center collar) at 11.6 ft
radius and 19.4 ft radius of the roof assembly.