Chapter 6: stiffeners – Grain Systems Tanks PNEG-4075 User Manual

Page 53

Advertising
background image

Chapter 6: Stiffeners

Close-Punch Connection for a Two-Ring Stiffener (0–14 Ga) to a
Two-Ring Stiffener (0–14 Ga)

Reference the following information for a close-punch connection of a two-ring stiffener (CTS-2073XX) to a
two-ring stiffener (CTS-2073XX).

Figure 6-12 Two-Ring Stiffener (0–14 Ga) to a Two-Ring Stiffener (0–14 Ga) Close-Punch Connection

A

Two-ring stiffener (CTS-2073XX)

B

Two-ring stiffener (CTS-2073XX)

C

Splice (CTS-2091XX)

D

3/8 x 1 Bolt (S-7485)

E

3/8 Nut (S-9426)

F

Completed assembly

NOTE: Two-post stiffeners shown. The bolt pattern will

vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.

Two-Ring Stiffener (0–14 Ga) to a Close-Punch Base Stiffener
(2–8 Ga) Connection

Reference the following information when connecting a two-ring stiffener (CTS-2063XX) to a close-punch
two-ring stiffener (CTS-2119XX).

Figure 6-13 Two-Ring Stiffener (0–14 Ga) to a Close-Punch Two-Ring Stiffener (2–8 Ga) Connection

A

Two-ring stiffener (CTS-2063XX)

B

Close-punch two-ring stiffener
(CTS-2119XX)

C

Splice (CTS-2091XX)

D

3/8 x 1 Bolt (S-7485)

E

3/8 Nut (S-9426)

F

Completed assembly

NOTE: Two-post stiffeners shown. The bolt pattern will

vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.

Pneg-4075 75 Ft Diameter 40-Series Bin

53

Advertising