Assembling the temperature cable bracket – Grain Systems Tanks PNEG-4075 User Manual

Page 78

Advertising
background image

Chapter 7: Roof Assembly

Assembling the Temperature Cable Bracket

The temperature cable brackets are installed to the roof rafters and support the temperature cables.

Before You Begin

Determine the correct location of the temperature cable brackets within the structure of the A-frame
Assembly. See

About Temperature Cable Brackets and A-Frame Assemblies, page 75

.

What You Should Know

The A-frame assembly consists of two roof rafters, purlin clips, purlins and possibly X-bracing. The temper-
ature cable brackets should be installed when the A-frames are assembled.

NOTE: The temperature cable bracket must be installed at specific locations, see

About Temperature

Cable Brackets and A-Frame Assemblies, page 75

.

1. Attach a right purlin clip (C), a left purlin clip (D) and a temperature cable bracket (B) to the roof rafter

(A), and install two flange bolts (E) and two flange nuts (F).

NOTE: If no X-bracing is installed, install three flange bolts (E) and three flange nuts (F).

2. After all purlins and X-bracing are installed in the A-frame, tighten all hardware to the recommended

torque specifications. See

Bolt Torque Specifications, page 24

.

78

Pneg-4075 75 Ft Diameter 40-Series Bin

Advertising