2 parameter list – GE Industrial Solutions AF-650 GP DeviceNet User Manual

Page 45

Advertising
background image

6.2 Parameter List

Par. No. # and Description

Default value

Range

Conversion
index

Data type

Par. O-00 Enabled options

All [1]

[0 - 7]

-

5

par. O-01 Control Site

Dig. & ctrl. word [0]

[0 - 2]

-

5

par. O-02 Control Word Source

Drive RS485 [0]

[0 - 4]

-

5

par. O-03 Control Word Timeout Time

1s

0.1-18000

-1

7

par. O-04 Control Word Timeout Function

Off [0]

[0 - 10]

-1

5

par. O-05 End-of-Timeout Function

Hold set-up [0]

[0 - 1]

-

5

par. O-06 Reset Control Word Timeout

Do not reset [0]

[0 - 1]

-

5

par. O-07 Diagnosis Trigger

Disable [0]

[0 - 3]

-

5

par. O-10 Control Word Profile

Drive protocol [0]

[0 - x]

-

5

par. O-50 Coasting Select

Logic OR [3]

[0 - 3]

-

5

par. O-51 Quick Stop Select

Logic OR [3]

[0 - 3]

-

5

par. O-52 DC Brake Select

Logic OR [3]

[0 - 3]

-

5

par. O-53 Start Select

Logic OR [3]

[0 - 3]

-

5

par. O-54 Reversing Select

Logic OR [3]

[0 - 3]

-

5

par. O-55 Set-up Select

Logic OR [3]

[0 - 3]

-

5

par. O-56 Preset Reference Select

Logic OR [3]

[0 - 3]

-

5

par. O-90 Bus Jog 1 Speed

100 rpm

0 - par. F-17 Motor Speed
High Limit [RPM]

67

6

par. O-91 Bus Jog 2 Speed

200 rpm

0 - par. F-17 Motor Speed
High Limit [RPM]

67

6

par. DN-00 DeviceNet Protocol

DeviceNet [1]

[0 - 1]

-

5

par. DN-01 Baud Rate Select

125 Kbps [20]

[20 - 22]

-

5

par. DN-02 MAC ID

63

0 - 63

0

5

par. DN-05 Readout Transmit Error Counter

0

0 - 255

0

5

par. DN-06 Readout Receive Error Counter

0

0 - 255

0

6

par. DN-07 Readout Bus Off Counter

0

0 - 1000

0

par. DN-10 Process Data Type Selection

[0]/[2]

[0 - 3]

0

5

par. DN-11 Process Data Config Write

0

list

0

5

par. DN-12 Process Data Config Read

0

list

0

5

par. DN-13 Warning Parameter

0

0 - FFFF

0

5

par. DN-14 Net Reference

Off [0]

[0 - 1]

-

5

par. DN-15 Net Control

Off [0]

[0 - 1]

-

5

par. DN-20 COS Filter 1

0

0 - FFFF

0

6

par. DN-21 COS Filter 2

0

0 - FFFF

0

6

par. DN-22 COS Filter 3

0

0 - FFFF

0

6

par. DN-23 COS Filter 4

0

0 - FFFF

0

6

par. DN-31 Store Data Values

Off [0]

[0 - 2]

-

5

par. DN-32 Devicenet Revision

-

-

-

6

par. DN-33 Store Always

Off [0]

[0 - 1]

-

5

par. DR-90 Alarm Word

0

0 - FFFF

0

7

par. DR-92 Warning Word

0

0 - FFFF

0

7

AF-600FP /650 GP DeviceNet Operating Instructions

44

6

Advertising