GE Industrial Solutions AF-650 GP PROFINET User Manual

Page 47

Advertising
background image

Parameter

Default value

Range

Conver-
sion index

Data type

EN-05 Lease Expires

00:00:00:00

-

-

Time diff. w/

date

EN-06 Name Servers

0.0.0.0

0 - 255

-

Oct. string 4

EN-07 Domain Name

-

max. 19 ch.

-

Visible string 48

EN-08 Host Name

-

max. 19 ch.

-

Visible string 48

EN-09 Physical Address

00:1B:08:00:00:00

-

-

Visible string 17

EN-10 Link Status

No Link [0]

[0 - 1]

-

Unsigned 8

EN-11 Link Duration

00:00:00:00

-

-

Time diff. w/

date

EN-12 Auto Negotiation

On [1]

[0 - 1]

-

Unsigned 8

EN-13 Link Speed

None [0]

[0 - 2]

-

Unsigned 8

EN-14 Link Duplex

Full Duplex [1]

[0 - 1]

-

Unsigned 8[

EN-80 FTP Server

Disable [0]

[0 – 1]

-

Unsigned 8

EN-81 HTTP Server

Disable [0]

[0 – 1]

-

Unsigned 8

EN-82 SMTP Service

Disable [0]

[0 – 1]

-

Unsigned 8

EN-89 Transparent Socket Channel Port

Disable [0]

[0 – 1]

-

Unsigned 8

EN-90 Cable Diagnostic

Disable [0]

[0 - 1]

-

Unsigned 8

EN-91 MDI-X

Enable [0]

[0 - 1]

-

Unsigned 8

EN-92 IGMP Snooping

Enable [0]

[0 - 1]

-

Unsigned 8

EN-93 Cable Error Length

0

0 - 200

0

Unsigned 16

EN-94 Broadcast Storm Protection

0

Off – 20%

-

Unsigned 16

EN-95 Broadcast Storm Filter

Enable [1]

[0 - 1]

-

Unsigned 8

EN-98 Interface Counters

0

0 - 65535

-

Unsigned 16

EN-99 Media Counters

0

0 - 65535

-

Unsigned 16

DR-84 Comm. Option STW

0

0 - FFFF

0

V2

DR-90 Alarm Word

0

0 - FFFF

0

Uint32

DR-92 Warning Word

0

0 - FFFF

0

Uint32

Table 8.2

Please refer to the relevant Operating Instructions for a comprehensive parameter list.

Parameters

PROFINET Operating Instruction

46

8

8

Advertising