9.1 E.g.: Process Data with PPO Type 6

This example shows how to work with PPO type 6, which consists of Control Word/Status Word and Reference/Main Actual
Value. The PPO also has two additional words, which can be programmed to monitor process signals:

PCD

0

1

2

3

CTW

MRV

PCD[2]

PCD

From Controller

04

7C

20

00

00

00

00

00

STW

MAV

PCD[2]

PCD[3]

From Drive

0F

07

20

00

3F

A6

00

08

Byte #

1

2

3

4

5

6

7

8

Table 9.1

The application requires monitoring of the motor torque and digital input, so PCD 2 is set up to read the current motor
torque. PCD 3 is set up to monitor the state of an external sensor via the process signal digital input. The sensor is
connected to digital input 18.

An external device is also controlled via control word bit 11 and the built-in relay of the frequency converter. Reversing is
permitted only when the reversing bit 15 in the control word and the digital input 19 are set to high.

For safety reasons the frequency converter will stop the motor if the PROFINET cable is broken, the master has a system
failure, or the PLC is in stop mode.