9.

Manual operation

The actuator may be operated manually for purposes of setting and commis-
sioning and in case of motor failure or power failure.
Manual operation is engaged by an internal change-over mechanism.

Engaging manual operation

.

Lift up change-over lever in the center of the handwheel to approx. 85°, while
slightly turning the handwheel back and forth until manual operation engages
(figure K-1).

Manual force is sufficient for operating the change-over lever. It
is not necessary to use an extension. Excessive force may
damage the change-over mechanism.

.

Release change-over lever (should snap back into initial position by spring
action, figure K), if necessary, push it back manually.

Operating the change-over lever while the motor is running
(figure L-1) can lead to increased wear at the change-over
mechanism.

.

Turn handwheel into desired direction (figure 13-2).

Disengaging manual operation

Manual operation is automatically disengaged when motor is started again.
The handwheel does not rotate during motor operation.

Multi-turn actuators SA 07.1 – SA 30.1/ SAR 07.1 – SAR 30.1

Operation instructions

with actuator controls AUMA MATIC AM 01.1 / AM 02.1

19

Figure K-1

Figure K-2

Figure L-1

Figure 13-2

Advertising