Technical data

Features and functions

Type of duty

1)

Standard:

SA

Short time duty S2 - 15 min

SAR

Intermittent duty S4 - 25 %

Option:

SA

Short time duty S2 - 30 min

SAR

Intermittent duty S4 - 50 %
Intermittent duty S5 – 25 %

Motors

Standard:

3-ph AC asynchronous motor, type IM B9 according to IEC 34

Option:

Special motors

Insulation class

Standard:

F, tropicalized

Option:

H, tropicalized

Motor protection

Standard:

Thermoswitches (NC)

Option:

PTC thermistors (according to DIN 44082)

Self-locking

Yes, for output speeds from 5.6 to 108 rpm

Limit switching

Counter gear mechanism for end positions CLOSED and OPEN
for 1 to 500 turns per stroke (optional for 1 to 5,000 turns per stroke)
Standard:

Tandem switch (2 NC and 2 NO) for each end position

Options:

Single switch (1 NC and 1 NO) for each end position,
switches galvanically isolated
Triple switch (3 NC and 3 NO) for each end position,
switches galvanically isolated
Intermediate position switch (DUO limit switching),
adjustable for any intermediate position

Torque switching

Infinitely adjustable torque switching for direction OPEN and CLOSE
Standard:

Single switch (1 NC and 1 NO) for each direction

Options:

Tandem switch (2 NC and 2 NO) for each direction, switches galvanically isolated

Position feedback signal,
analogue (options)

Potentiometer or 0/4 – 20 mA (RWG)
For further details, see separate data sheet

Mechanical position indicator
(option)

Continuous indication, adjustable indicator disc with symbols OPEN and CLOSED

Running indication (option)

Blinker transmitter

Heater in switch compartment

Standard:

Resistance type heater with 5 W, 24 V DC

Options:

Self-regulating PTC heater, 5 – 20 W
24 – 48 V AC/DC, 110 – 250 V AC/DC or 380 – 400 V AC

Motor heater (option)

SA(R) 07.1 – 10.1:

12.5 W

SA(R) 14.1 – 16.1:

25 W

SA(R) 25.1 – 30.1:

50 W

Manual operation

Manual drive for setting and emergency operation, handwheel does not rotate during electrical operation.
Option:

Handwheel lockable

Connection to controls

AUMA plug/ socket connector with screw type connection

Output drive types

A, B1, B2, B3, B4 according to EN ISO 5210
A, B, D, E according to DIN 3210
C according to DIN 3338
Special output drives: AF, AK, AG, IB1, IB3

Power supply, mains frequency
and current consumption

For mains voltage and mains frequency, refer to name plates at the controls and the motor
Permissible variation of the nominal voltage: ± 10 %
Permissible variation of the mains frequency: ± 5 %
Motor current consumption: Refer to motor name plate
Current consumption of the controls depending on the mains voltage:
100 to 120 V AC = max. 600 mA
208 to 240 V AC = max. 300 mA
380 to 500 V AC = max. 150 mA

External supply of the
electronics (option)

24 V DC + 20 % / – 15 %,
Observe current consumption of the controls

Rated power

Refer to motor name plate
Note: The controls is designed for the rated power of the actuator

Overvoltage category

Category III

1) Based on 68 °F ambient temperature and at an average load with running torque according to Technical data SA or SAR

Multi-turn actuators SA 07.1 – SA 30.1/ SAR 07.1 – SAR 30.1