CommissioninG

English

To expand the system with a remote RIO module (expansion by 16DI/16DO) proceed as follows:

Pull the module RIO DI16/DO16 into the slave, Type 8645/MK01 (drag and drop).

The following module types are available:

Module types
RIO DI16/DO16

RIO-Modul: 2 byte inputs , 2 byte outputs

RIO DI8/DO8

RIO-Modul: 1 byte inputs , 1 byte outputs

RIO only DI8

RIO-Modul: 1 byte inputs

RIO only DO8

RIO-Modul: 1 byte outputs

Add-on DI8

Expansion module: 1 byte inputs

Add-on DO8

Expansion module: 1 byte outputs

A RIO module must be used for each hardware configuration . The add-on modules can be used to fill empty
spaces up to 2 bytes IN or 2 bytes OUT.


Different examples of hardware configuration

Illustration: Example configuration with 16IN/16OUT (Main module); 16IN/16OUT (Intermediate module);

16IN/16OUT (RIO module)

Illustration: Example configuration with 8 IN/8 OUT (Main module); 8 IN/8 OUT (Intermediate module) and

8 IN/8 OUT (RIO module) each with add-on DO8 and DI8

With this configuration (8 IN / 8 OUT with add-on DO8 and DI8), you can freely assign the addresses for the
second output andn input byte. This is not possible with the main/inside DI16/DO16 or RIO DI16/DO16 mo-
dule. The second byte is automatically one address higher than the first byte.