Pneumatic data, Dimensions, Pneumatic data dimensions – Burkert Type 8645 User Manual

Page 89: Configuration and function of the modules english

Advertising
background image

ConfiGuraTion anD funCTion of The moDules

English

8645 - 89

Pneumatic data

valve type

6524
3/2-way

6525
5/2-way

6524
2x 3/2-way

0460
5/2-way pulse,
5/3-way

Method of operation

1)

C/D

H

2 x C

H pulse, L, N

Nominal size [mm]

4

2.5

QNn

2)

[l/min]

00

200

Opening time

)

10 % [ms]

12

15

Closing time

)

10 % [ms]

20

H = 15 / L, N = 20

Pressure range

4)

[bar]

2.5 to 7
Vacuum to 7
Vacuum to 10

2.5 to 7
Vaccum to 7
Vacuum to 10

2.5 to 7
1 to 7
Vacuum to 10

2 to 7

Output [W]

1

1

2

0.9

Output [W]
after pick-up time (<120 ms)

1/4

1/4

1/2

1/4

Displays

1 LED per valve function

1)

C=NC (normally closed), D=NO (normally open), L=APB (all parts blocked), N=APO (all parts open)

2)

Flow rate QNn value air [l/min]: Measured at +20 °C, Pressure 6 bar at valve entry and 1 bar pressure difference

)

Switching times [ms]: Measured to ISO 12238

4)

Pressure data [bar]: Overpressure with respect to atmospheric pressure

dimensions

6.75

79.5

35.5

6.2

17.5

37

1)

A

0

9.5

31

37

51

57

124

131.54

138.2

8.5 21.5

50.7

Ш3,

2

Ш3.2

3.5

12.5

37

1)

98.35

17.5

11.4

23

130.5

Illustration: Dimensions [mm] - Combination Module

Advertising