Storage, Decommissioning, Restarting – Burkert Type 8645 User Manual

Page 164: Storage, disposal english

Advertising
background image

164 - 8645

sToraGe, Disposal

English

STORAGE

Storag�e conditions for Modules in Orig�inal Packag�ing�

The following information applies to modules stored in their original packaging.

Requirement

Admissible range

Temperature

-20 to +60 °C

Temperature change

20 K/h

Atmospheric pressure

1080 to 660 hPa (corresponding to an altitude of -1000 m to +500 m)

Relative humidity

5 to 95 %, non-condensing

decommissioning�

cAuTION!

The system is live.
Inverventions may result in an acute risk of injury.
Always switch off the power supply before starting work!

The system is pressurised.
Risk of injury when loosening or removing lines or modules.
Depressurise the system before starting work!

Shut down the system as follows:

Depressurise the system.

Switch off the power supply.

Dismantle the system and modules.

Store the system / modules in the original packaging.

Restarting�

Put the system into operation again as follows:

Unpack the system / modules and allow them to acclimatise to the ambient conditions.

Then proceed as described in chapters

Installation and Commissioning.