Waveform data encryption, Commands for, Commands for downloading and extracting – Agilent Technologies N5183A MXG User Manual

Page 214

Advertising
background image

204

Agilent N518xA, E8663B, E44x8C, and E82x7D Signal Generators Programming Guide

Creating and Downloading Waveform Files
Commands for Downloading and Extracting Waveform Data

Commands for Downloading and Extracting Waveform Data

You can download I/Q data, the associated file header, and marker file information (collectively called
waveform data) into volatile or non- volatile memory. For information on waveform structure, see

“Waveform Structure” on page 193

.

The signal generator provides the option of downloading waveform data either for extraction or not
for extraction. When you extract waveform data, the signal generator may require it to be read out in
encrypted form. The SCPI download commands determine whether the waveform data is extractable.

If you use SCPI commands to download waveform data to be extracted later, you must use the
MEM:DATA:UNPRotected

command. If you use FTP commands, no special command syntax is

necessary.

NOTE

On the N5182A, :MEM:DATA enables file extraction. On the N5182A the
:MEM:DATA:UNPRotected

command is not required to enable file extraction. For more

information, refer to the SCPI Command Reference.

You can download or extract waveform data created in any of the following ways:

with signal simulation software, such as MATLAB or Agilent Advanced Design System (ADS)

with advanced programming languages, such as C++, VB or VEE

with Agilent Signal Studio software

with the signal generator

Waveform Data Encryption

You can download encrypted waveform data extracted from one signal generator into another signal
generator with the same option or software license for the modulation format. You can also extract
encrypted waveform data created with software such as MATLAB or ADS, providing the data was
downloaded to the signal generator using the proper command.

When you generate a waveform from the signal generator’s internal ARB modulation format
(ESG/PSG only), the resulting waveform data is automatically stored in volatile memory and is
available for extraction as an encrypted file.

When you download an exported waveform using a Agilent Signal Studio software product, you can
use the FTP process and the securewave directory or SCPI commands, to extract the encrypted file
to the non- volatile memory on the signal generator. Refer to

“File Transfer Methods” on page 205

.

Table 5-6

E4438C and E8267D Non-Volatile (NVWFM) Memory

Non- Volatile (NVWFM) Memory

Option

Size

E4438C and E8267D

Standard

3 MSa (15 MB)

005 (Hard disk)

1.2 GSa (6 GB)

Advertising
This manual is related to the following products: