Agilent N518xA, E8663B, E44x8C, and E82x7D Signal Generators Programming Guide

Creating and Downloading Waveform Files
Programming Examples

[status, status_description] = agt_sendcommand(io, 'SOURce:FREQuency 20000000000');

[status, status_description] = agt_sendcommand(io, 'POWer 0');

% define the ARB sample clock for playback

sampclk = 40000000;

% download the iq waveform to the PSG baseband generator for playback

[status, status_description] = agt_waveformload(io, IQData, 'pulsepat', sampclk, 'play', 'no_normscale',
Markers);

% turn on RF output power

[status, status_description ] = agt_sendcommand( io, 'OUTPut:STATe ON' )

You can test your program by performing a simulated plot of the in- phase modulation signal in
Matlab (see

Figure 5- 2 on page 260

). To do this, enter plot (i) at the Matlab command prompt.

Figure 5-2

Simulated Plot of In-Phase Signal

The following additional Matlab M- file pulse programming examples are also available on the
Documentation CD- ROM for your Agilent MXG and PSG signal generator: