Queries using hp basic and gpib – Agilent Technologies N5183A MXG User Manual

Page 82

Advertising
background image

72

Agilent N518xA, E8663B, E44x8C, and E82x7D Signal Generators Programming Guide

Programming Examples
GPIB Programming Interface Examples

SetRWLS(GPIB0, Address); // Places device in Remote with Lockout State.

cout<< "The signal generator should now be in LOCAL LOCKOUT. Verify that all

keys"<<endl;

cout<< "including the 'Local' key are disabled (Contrast keys are not

affected)"<<endl;

cout <<"Press Enter to continue"<<endl;

cin.ignore(10000,'\n');

ibloc(sig); // Returns signal generator to local control

cout<<endl;

cout <<"The signal generator should now be in local mode\n";

return 0;}

}

Queries Using HP Basic and GPIB

This example demonstrates signal generator query commands. The signal generator can be queried for
conditions and setup parameters. Query commands are identified by the question mark as in the
identify command *IDN? basicex3.txt performs the following functions:

clears the signal generator

queries the signal generator’s settings

The following program example is available on the signal generator Documentation CD- ROM as
basicex3.txt

.

10 !********************************************************************************

20 !

30 ! PROGRAM NAME: basicex3.txt

40 !

50 ! PROGRAM DESCRIPTION: In this example, query commands are used with response

60 ! data formats.

70 !

80 ! CLEAR and RESET the controller and RUN the following program:

90 !

100 !********************************************************************************

110 !

120 DIM A$[10],C$[100],D$[10] ! Declares variables to hold string response data

130 INTEGER B ! Declares variable to hold integer response data

140 Sig_gen=719 ! Declares variable to hold signal generator address

150 LOCAL Sig_gen ! Puts signal generator in Local mode

160 CLEAR Sig_gen ! Resets parser and clears any pending output

170 CLEAR SCREEN ! Clears the controller’s display

180 OUTPUT Sig_gen;"*RST" ! Puts signal generator into a defined state

190 OUTPUT Sig_gen;"FREQ:CW?" ! Querys the signal generator CW frequency setting

200 ENTER Sig_gen;F ! Enter the CW frequency setting

210 ! Print frequency setting to the controller display