Creating and Downloading Waveform Files
Downloading Waveform Data

2. Download the I/Q data

The following code downloads the generated waveform data to the signal generator, and if the
download fails, displays a message.

Line

Code Description—Open a Connection Session with the Signal Generator

1

Sets up a structure (indicated above by io) used by subsequent function calls to establish a LAN connection to
the signal generator.

agt_newconnection() is the function of Agilent Waveform Download Assistant used in MATLAB to build a
connection to the signal generator.

If you are using GPIB to connect to the signal generator, provide the board, primary address, and
secondary address: io = agt_newconnection('gpib',0,19);
Change the GPIB address based on your instrument setting.

2

Send a query to the signal generator to verify the connection.

agt_query() is an Agilent Waveform Download Assistant function that sends a query to the signal
generator.

If signal generator receives the query *idn?, status returns zero and query_result returns the signal
generator’s model number, serial number, and firmware version.

3–5

If the query fails, display a message.

Line

Code—Download the I/Q data

6

7
8
9

[status, status_description] = agt_waveformload(io, IQwave,

'waveformfile1', 2000, 'no_play','norm_scale');

if status == -1

display ‘fail to download to the signal generator’;

end;