User fir filter coefficient file download problems – Agilent Technologies N5183A MXG User Manual

Page 353

Advertising
background image

Agilent N518xA, E8663B, E44x8C, and E82x7D Signal Generators Programming Guide

343

Creating and Downloading User-Data Files

Data Transfer Troubleshooting (N5182A, E4438C and E8267D Only)

User FIR Filter Coefficient File Download Problems

Data Requirements

Data must be in ASCII format.

Downloads must be in list format.

Filters containing more symbols than the hardware allows (64 for real- time and 512 for Arb) will
not be selectable for the configuration.

Table 8-15 User FIR File Download Trouble - Symptoms and Causes

Symptom

Possible Cause

ERROR - 321, Out of memory

There is not enough memory available for the FIR coefficient file being
downloaded.

To solve the problem, either reduce the file size of the FIR file or delete
unnecessary files from memory.

ERROR - 223, Too much data

User FIR filter has too many symbols.

Real- Time cannot use a filter that has more than 64 symbols (512
symbols maximum for Arb). You may have specified an incorrect
oversample ratio in the filter table editor.

Advertising