Fairbanks H90-5200-A Digital Instrument User Manual

Page 21

Advertising
background image

AA is the weight, BB is the weight unit, and X is the corresponding setpoint
number.

j. Steps d - i will be repeated until the last setpoint has been reached. If batch

print mode is enabled, a weight total will be printed.

k. The instrument will switch back to the first ingredient setpoint.

I. The setpoint outputs will remain OFF and the unit will return to normal

operation in the GROSS mode.

If the batching is stopped in the middle of the cycle, it may be restarted where it left off
(Step h) by pressing the FUNC, START keys or started at the beginning of the current
ingredient setpoint (Step g) by pressing the START key. The current setpoint can be
changed by pressing the STOP key until the desired setpoint indicator is lit. The TRIM
Key is not functional in this mode.

IMPORTANT NOTES

1. The front panel STOP key should never be used as the primary STOP control

(EMERGENCY STOP) in a critical batching operation.

2. The batch cycle will automatically stop if any operation interrupts the weight

monitoring process. For example, if print, zero or tare operations are initiated
during weight operations.

Up to 4 setpoints may be enabled depending on settings of : dribble, preact, discharge,
zeroband, setpoint inhibit, SP auto zero, delay 1 and print options.

MODE 5- AUTO BATCH REPEAT MODE

Display shows “SP Abr”:
The Auto Batching with Repeat mode operates the same as the Auto Batch mode
except that instead of stopping after each batching cycle is complete the unit will
automatically return to the first setpoint and start a new cycle after a delay of length
DELAY2. When the START button is pressed, if the instrument is not inhibited from
operating by the setpoint inhibit (refer to setpoint operation), the following sequence
will occur:

a. If Setpoint 1 (SP 1) is enabled and the Setpoint Autozero feature is enabled,

then the scale will be zeroed.

b. An autotare will occur and the indicator will switch to NET mode.
c. The first ingredient output(s) will turn on until the setpoint is reached.
d. The “ENABLED” indicator will start to flash and the delay time out will start. (If

the DELAY 1 = 0, an infinite delay will occur and START must be pressed.)

e. At the end of the delay, a print operation will occur if the batch print mode is

enabled.

f. The instrument will switch to the next ingredient setpoint.
g. The “ENABLE” indicator stops flashing and an autotare will occur.
h. The setpoint is enabled.
i. When the displayed weight reaches the setpoint, the output will turn off.

50515

21

Issue #2 4/04

Advertising