Programming Setpoint Values

1. Press FUNC, 1. The display will show “SP CAL” Enter the number of the setpoint

you wish to program, 1 – 5. If paired setpoints are used (dribble is enabled), then
enter 1 or 3 to program the setpoint value and 2 or 4 to program the dribble value.

Always enter 5 to program Setpoint Software Inhibit.

2. The selected setpoint indicator will turn ON and the display will alternately flash

between a legend and the current value programmed. The legend will be “SP” for
setpoint, “DR” for dribble, or “SPi” for setpoint software inhibit, or “2b” for zeroband.

3. Enter a new value from the keypad or press ENTER to store the current value in

memory.

4. If Preact is enabled, the instrument will now prompt the user to enter the Preact

value to be used. There is a separate preact available for each output.

5. The unit will now return to normal weigh mode.

SETPOINT Outputs

The setpoint output terminal block, is located in the bottom of the instrument. The
setpoint output cable is connected to J3 (pins 10-16) on the main PC Board, near the
AC power connector.

The setpoint control cable will exit the instrument through the waterproof gland on the
back (see Figure 2417, page 11). Refer to Appendix VII to identify setpoint outputs at

TB3.

50515

26

Issue #2 4/04

Power
Supply

1

1

1

24

13

12

JP1

JP2

JP7

JP6

JP3

1

1

1

7

14

8

Load Cell
Connector

50514-2

6 7 8 9

11

12 13

14

15

16

J3

1 2 3 4 5

RS232

C. Loop

Set Points