background image

Discharge cycle starts IF enabled

ENTER ID

<STX>EIXXXXXX<CR><ETX>
Product ID is entered into memory (XXXX =ID is desired)

RECALL ID

<STX>RI<CR><ETX>
ID is output

ENTER TARE

<STX>ETXXXXXX{L / K}<CR><ETX>
Tare is entered into memory. IF an illegal tare is used, it will be
cleared. L(LB) OR K(KG) can be used to request output in a
specific weight unit

RECALL TARE

<STX>RT{L/K}<CR><ETX>
Tare is output.
L(LB) OR K(KG) can be used to request output in a specific
weight unit

RECALL CONFIG <STX>RC<CR><ETX>

Config/Calibration parameters are output

ENTER SETPOINT <STX>ESM[x][NI][Dy][Py][Cy][Zy][lz][Ay][T1xx][T2xx][Oy]<CR><ETX>

RECALL CONFIG <STX>RC<CR><ETX>

Model, Progam Rev,Time, Date, Cap, Cal Data: Current
Zero______S________ Diag Test 1_______2_______

Note: ONLY 7 variables can be entered at one time

C

=Discharge/Dump

I

=Setpoint Inhibit

A

=Auto zero at batch start

O

=Output (Autoprint)

T1

=Delay Timer1

T2

=Delay Timer2

M

=Mode

x

=0 (Setpoints disabled)

x

=1 (Setpoint mode)

x

=2 (Checkweigh mode)

x

=3 (Batch mode)

x

=4 (Autobatch mode)

x

=5 (Autobatch repeat mode)

x

=Anything else (Setpoints disabled)

N

=number of ingredients

I

=1,2,3,4

D

=Dribble

P

=Preact

Z

=Zeroband