Fairbanks H90-5200-A Digital Instrument User Manual
Page 32
Discharge cycle starts IF enabled
ENTER ID
<STX>EIXXXXXX<CR><ETX>
Product ID is entered into memory (XXXX =ID is desired)
RECALL ID
<STX>RI<CR><ETX>
ID is output
ENTER TARE
<STX>ETXXXXXX{L / K}<CR><ETX>
Tare is entered into memory. IF an illegal tare is used, it will be
cleared. L(LB) OR K(KG) can be used to request output in a
specific weight unit
RECALL TARE
<STX>RT{L/K}<CR><ETX>
Tare is output.
L(LB) OR K(KG) can be used to request output in a specific
weight unit
RECALL CONFIG <STX>RC<CR><ETX>
Config/Calibration parameters are output
ENTER SETPOINT <STX>ESM[x][NI][Dy][Py][Cy][Zy][lz][Ay][T1xx][T2xx][Oy]<CR><ETX>
RECALL CONFIG <STX>RC<CR><ETX>
Model, Progam Rev,Time, Date, Cap, Cal Data: Current
Zero______S________ Diag Test 1_______2_______
Note: ONLY 7 variables can be entered at one time
C
=Discharge/Dump
I
=Setpoint Inhibit
A
=Auto zero at batch start
O
=Output (Autoprint)
T1
=Delay Timer1
T2
=Delay Timer2
M
=Mode
x
=0 (Setpoints disabled)
x
=1 (Setpoint mode)
x
=2 (Checkweigh mode)
x
=3 (Batch mode)
x
=4 (Autobatch mode)
x
=5 (Autobatch repeat mode)
x
=Anything else (Setpoints disabled)
N
=number of ingredients
I
=1,2,3,4
D
=Dribble
P
=Preact
Z
=Zeroband
50515
32
Issue #2 4/04