Cut to Length with Multi Stroke Program

C. ENABLE INPUT (J4)Pin 5 & 6)

The enable input is shipped from the factory, jumpered, so that the Pac-Sci
unit is ready to work after the initialization procedure is complete.

If it is desired that the servo controls are not functional until other equipment
or safety source is activated before this unit can function then a normally open
contact can be interfaced to this input. If at any time during the feed cycle the
input changes state then the feed will stop at this position. If feeding stock,
the reference will be lost and the stock will have to be manually repositioned
to the correct location. The automatic cycle will be dropped and have to be
restarted.

D. ENABLE OUTPUT (J52)TB2-15)

This output must be tied to a solid state relay to interface to the outside world.
The solid state relay must have a D.C. coil and should have a rating of 3-30
VDC. The Rapid-Air #69100165 is recommended for this application. This
output is high whenever the enabled input is activated.

E. CUTTER OUTPUT (J52)TB2-13)

This output must be tied to a solid state relay to interface to the outside world.
The solid state relay must have a D.C. coil and should have a rating of 3-30
VDC. The Rapid-Air #69100165 is recommended for this application. This
output goes high at the end of every feed and stays high for the amount of
time programmed by the operator when the job number was programmed.