Triton RL5000 Installation Manual User Manual

Page 22

Advertising
background image

2 2

RL5000 S

ERIES

I

NSTALLATION

G

UIDE

6.

Use a torque wrench and 3/8”
socket to tighten each nut to a
torque setting of 60 foot-pounds
(required to establish the
maximum pull-out strength of the
anchors)
. If a torque wrench is not
available, use a ratchet wrench and
3/8” socket to tighten the nuts three
full turns beyond hand tight
.

7.

Once all anchor bolts are tightened,
close the door of the cabinet to
ensure that the door opens and
closes without binding.

If the door does bind, it may be
necessary to relocate the cabinet
to an area with a flat level floor!

If a Business Hours cabinet was
installed with leveling feet, the
feet may have caused the warping
of the cabinet bottom under
pressure of the mounting bolts.

8.

Once the nuts are tightened as
specified in Step 6 and the door
operates without binding as
verified in Step 7, install a second
nut on each bolt and tighten down
firmly
.

9.

If the dispenser tray was removed
to facilitate cabinet installation,
replace it at this time.

Fig. 1. Drilling mounting

holes.

Fig. 2. “Sleeve”-type anchor

bolt.

Fig. 3. Place anchor bolts in

mounting holes.

Fig. 4. Tap anchor bolts into

mounting holes.

5.

Ensure the cabinet is as level as
possible given the floor conditions.
Use a bubble level to verify this. If
a bubble-level is not available, the
cabinet can be “rocked” gently
from front-to-back and side-to-side
to check the need for leveling.