Nmd-50 d – Triton RL5000 Installation Manual User Manual

Page 50

Advertising
background image

5 0

I

NSTALLING

THE

NMD-50

D

ISPENSING

M

ECHANISM

The dispensing mechanism for the
RL5000 may be shipped hanging on
the side rails inside the security cabi-
net. Several protective foam blocks have
been strategically placed behind and
along each side of the dispensing
mechanism to reduce any movement
during transit. The foam blocks must
be removed before the dispenser can
be installed. If the dispenser is shipped
inside the cabinet, follow the procedures
below for removal.

R

EMOVING

THE

D

ISPENSING

M

ECHA

-

NISM

FROM

THE

C

ABINET

2.

Open the cabinet door and remove
the cassettes (packed in boxes) and
the accessory kit.

3.

Remove all of the foam blocks from
around the dispensing mechanism.

Figure 4. Push in on the mechanical
stops (on both sides of the dispenser)
to allow the dispenser to be pulled off
the rails.

Figure 2. The NMD-50 dispensing
mechanism fully extended on its
mounting rails.

RL5000 S

ERIES

I

NSTALLATION

G

UIDE

1.

Refer to Figure 1. Unlock and open
the control panel. Verify that the
power switch is in the OFF (0)
position. Close the control panel.

Figure 1. Power switch on left side of
power module.

Figure 3. Disconnect the DC power
and serial communication connectors
from the dispensing mechanism.

Serial communications cable

DC power cable