The ATM is quite tolerant of power
line variations primarily because of
its built-in surge suppressor.
However, AC power for the terminal
should come from a dedicated
source with an isolated ground.
Route the AC power cord and the
phone cord out through the hole
in the back of the cabinet and install
the split ring grommet into the hole.

9.

Connect the AC input plug to the

wall outlet (See Note, below).

**IMPORTANT**

Electrical rating of the ATM: 200-
250 VAC, 50-60 Hz, 2.60 amps.

The ATM is designed to work
on an IT (Isolated Terra)-type
power system having a phase-
to-phase voltage not exceeding
250 volts.

The AC socket-outlet shall be
installed near the equipment
and shall be easily accessible.

POWER SUPPLY CORD - SPECIFICATIONS

For European applications, the power supply cord must conform to the following
specifications:

1.)

Two-conductor with Protective Earth (PE) ground.

2.)

IEC 320 molded connector on one end and molded plug on the other
end.

3.)

Certified for country of installation.

4.)

Rated minimum H05VV-F with minimum 0.75 mm

2

(except where specific

countries require 1.0 mm

2

) conductors.

5.)

Maximum length: 3 meters.

Figure 4. Installing the dispensing
mechanism.

Figure 3. Connections for DC power
and communications.

Cable 9600-0043

Cable 9600-0013