Connecting ac power and telephone line – Triton RL5000 Installation Manual User Manual

Page 36

Advertising
background image

3 6

RL5000 S

ERIES

I

NSTALLATION

G

UIDE

Connecting AC Power and

Telephone Line

IMPORTANT: AC power for the ter-
minal should come from a dedicated

source with an isolated ground.

1.

Ensure the power and phone cables
are routed through the cable clips
as shown in Figure 1.

2.

Route the AC power cord and the
phone cord through either the rear
or side access hole (as applicable)
in the security cabinet as shown in
Figures 2a and 2b.

POWER SUPPLY CORD -

SPECIFICATIONS

For European applications, the power
supply cord must conform to the fol-
lowing specifications:

1.

Two-conductor with Physical
Earth (PE) ground.

2.

IEC 320 molded connector on one
end and molded plug on the other
end.

3.

Certified for country of
installation.

4.

Rated minimum H05VV-F with
minimum 0.75 mm2 (except where
specfic countries require 1.0 mm2)
conductors.

5.

Maximum length: 3 meters.

Figure 1. Ensure power and phone
cords are routed through cable clips.

**WARNING**

This unit may be equipped with more
than one power cord. Disconnect All
Power Cords prior to Servicing!
For
continued fault protection, follow the
correct voltage and current ratings
when replacing any fuses.

Advertising