1.

Move the ATM into position for
mounting by aligning the base over
the four holes drilled in the
previous procedure.

2.

Begin by inserting a chemical stud
capsule into one of the mounting
holes. Either end of the capsule may
be inserted first.

3.

Place a washer and a nut (in that
order) onto a chisel point rod.
Thread the nut onto the rod leaving
3 to 4 threads exposed.

4.

Thread the rod coupler onto the
threaded rod until it is tight against
the nut. The threaded rod used
should be free of dirt, grease, oil or
other foreign material.

5.

Select the drive unit, insert it into a
rotary hammer drill and engage the
coupling to be used.

6.

Insert the chisel point of the rod
into the hole to break the glass
capsule. Spin it into the capsule at
a speed of 250 to 500 RPM until it
is fully embedded. IMPORTANT!
Turn the rotary hammer drill OFF
IMMEDIATELY when the rod is
fully embedded!

7.

Pull the driver out of the coupling
while holding the rod. Hold the hex
nut with a wrench to unthread the
coupler.

Fig. 4. Insert chemical stud
capsule in mounting hole.

Fig. 5. Prepare chisel point
anchor rod. Add washer and nut.

Fig. 6. Drive anchor rod into
capsule using hammer drill.

INSTALL CHEMICAL

ANCHORS