120/240 VAC Input (option board 2)

The line voltage input is available on option board 2. It can be configured for 120 or 240 volt input using
jumper pins 1. For 120 volt input jumper both sets of outside pins (see decal on board). For 240 volt
input jumper only the center two pins (see decal). NOTE – board is factory set for 120 volt input.

Figure 8: 120/240 VAC Input

Batch Controller Inputs (option board 3)

Five inputs are available for remote control of the batch process. You must have ordered the batch
model to access these inputs (MX9-B). A 15 VDC output is provided as a supply for the inputs. Program
/ Run uses a maintained contact (switch), and the other inputs require momentary signals.

Figure 9: Batch Controller Inputs