Restoring Factory Defaults

To restore the unit to factory default settings, a special “CLEAN SWEEP” function is available through the
MX 9000 serial number screen. From the serial number screen, press and hold the

ENTER

button for 3

seconds to reach the password screen. Enter “12356” using the

DOWN – UP – SELECT

buttons then

push

ENTER

. The “CLEAN SWEEP” screen will appear. This function can take up to 45 seconds to

complete – DO NOT TURN OFF OR INTERRUPT POWER DURING THIS OPERATION!

Performing a “CLEAN SWEEP” operation will erase

ALL

programmed information including K-factors,

linearizer tables and output limits programming. Current loop calibrations will also be set to default
values and will need to be reset. Use this function ONLY when all other troubleshooting methods have
failed and unstable operation of the controller remains. It is strongly suggested that the status screen
be viewed prior to performing a restore defaults to see if the raw data shown on it looks nominal to the
current process. Also make sure the K-Factor or linearizer table data is available for reprogramming as
these values will all be lost.