MX 9000 Process Monitor

Operation and Programming Manual

18

MX 9000 User Manual, Rev. 2.0 7/16/2013

The GRAND TOTAL screen can be accessed using the

ENTER

button from the TOTAL screen. To reset this

total pressing the

RESET

button will request the user to enter a password at this point. Use the

UP –

DOWN – SELECT

buttons to enter the password code of “53126”. Then press the

RESET

button which

will reset the grand total value back to zero (0). Note that both grand totals must be reset independent
of one another.

STATUS screen




The STATUS screen is a raw data display of the current major properties of the monitor. The rates are
shown as Hz, total in pulses, limits as on or off and current loop output (main loop only) in programmed
mA DC. NOTE: The Gate Time filter and linearizer, if active, do not affect the flow rate value in the
STATUS screen. This is the raw incoming frequency.
The mA shown is not a direct reading of the loop
current if there are other problems outside of the controller such as a broken wire or defective loop
power source. NOTE: Because the mA value is an actual signal output, it is affected by the Gate Time
and linearizer, if activated.
You can also access screen control programming from this screen by
pushing and holding the

ENTER

button for 3 seconds. Use the

UP – DOWN – SELECT

buttons to enter

the password code of “53126”. This password cannot be changed. See the advanced programming
section for further information on this process.

RATIO A/B (B/A) screens




The ratio A/B (B/A) screens show the mathematical relationship of the two flows of dual channel units.
NOTE: the units of both flows must be the same for this display to work properly.

RA, TA (RB, TB) screens





STATUS L1 OFF L2 OFF
RTA 100.14 TOA 15400
RTB 150.32 TOB 03561
ANLG 04.00 mA

RATIO AB (BA)

1.00

RA

1234.56

GPM

TA

123456.00

GAL