ANALOG OUTPUT


If your model was ordered with the 4-20 mA analog output option, one additional mode is available to
reflect the batch selected for remote monitoring. Selecting the analog output for “Mode” will result in a
current loop value directly proportional to the batch number in use. Refer to the following table:









OPERATION

To run a batch, select one of the pre-programmed ones using the batch select switch, then press the
start / stop switch. Note that any of the 20 presets that are programmed with 0 for both limits will be
skipped. Immediately the low flow output (relay 2) will energize and the display will indicate “RUN”. If
no delay is programmed, relay 1 will also energize (high flow), otherwise the delay will time out and
then it will energize. When limit 1 (S1) is reached, relay 1 will turn off slowing the flow at that point.
When limit 2 (S2) is reached, relay 2 will shut off stopping the flow and the display will say “DONE”. If
the start / stop button is pressed during a run, both outputs will be turned off and the display will read
“PAUSE”.












11 – 9.0 mA
12 – 9.5 mA
13 – 10.0 mA
14 – 10.5 mA
15 – 11.0 mA
16 – 11.5 mA
17 – 12.0 mA
18 – 12.5 mA
19 – 13.0 mA
20 – 13.5 mA

1 – 4.0 mA
2 – 4.5 mA
3 – 5.0 mA
4 – 5.5 mA
5 – 6.0 mA
6 – 6.5 mA
7 – 7.0 mA
8 – 7.5 mA
9 – 8.0 mA
10 – 8.5 mA

#1 BATCH TOTAL DONE

0.00

GAL

S1 0000.0 S2 0000.0