Analog out screen, L1/l2 screen – AW Gear Meters MX 9000 User Manual

Page 20

Advertising
background image

MX 9000 Process Monitor

Operation and Programming Manual

19

MX 9000 User Manual, Rev. 2.0 7/16/2013

The dual rate / total screen are a convenient way of showing both the flow and total at the same time.
Pressing the

RESET

button resets the total value back to zero (0). If the gate time or linearizer are active

those will also be indicated by a LN in the lower left or GT in the lower right of the display. By pushing
the

ENTER

key you can change the total displayed to grand total and will be indicated by a GA or GB in

front of the total.

ANALOG OUT screen





ANALOG OUT screen shows the mA value the MX 9000 is outputting. The 2 letters in the upper right
corner indicate what variable the mA output has been assigned to represent.

1. FX = Fixed mA output
2. RA = mA output is scaled to represent the RATE value
3. TO = mA output is scaled to represent the TOTAL value
4. GR = mA output is scaled to represent the GRAND TOTAL value

If the linearizer is active, ‘LN’ shows in lower left corner. If the Gate Time filter is active, ‘GT’ shows in
lower right corner.

L1/L2 screen






The L1/L2 screen shows what the Limits are programmed to represent and the state of the output.
The first line of each limit represents what the Limit is programmed for:

1. OFF – Limit output has been turned off.
2. Rate – The Limit output will change state when the flow rate reaches the programmed value
3. Total – The Limit output will change when the TOTAL reaches the programmed value
4. Grand Total - The Limit output will change when the GRAND TOTAL reaches the programmed

value

The second line of each limit represents the actual state of the output pin(s)


ANALOG OUT RA

04.00

mA

LN GT

L1

OFF

OFF

L2

OFF

OFF