Agilent Technologies AGILENT U2761A User Manual

Page 61

Advertising
background image

Features and Functions

2

U2761A User’s Guide

43

Example 2, To output a Sine wave

Example 3, To output a Square wave

-> *CLS

; *RST

//To reset the U2761A to default

power

-on state, this command can

be ignored if this operation is not
required.

-> FUNC SIN

//Sets the output to Sine wave.

-> VOLT 5 VPP

//Sets the output amplitude to 5 Vpp.

-> FREQ 1000

//Sets the output frequency to 1 kHz.

-> VOLT:OFFS 0

//Sets the output offset to 0.

-> OUTP ON

//Turns on output.

-> *CLS

; *RST

//To reset the U2761A to

default power

-on state,

this command can be
ignored if this operation
is not required.

-> APPL:SQU 2000,5 VPP,0

//Sets the output to Square

wave, frequency 2 kHz,
amplitude
5 Vpp, offset 0.

-> FUNC:SQU:DCYC 30

//Changes the duty cycle to

30%.

-> OUTP ON

//Turns on output.

Advertising