Using the command line interface 296

Since none of the configured device bay iLO have an IP address in the zero-conf IP address range, you must

manually add a network route on the laptop or PC if you need to access the iLO IP address from the service
port. The syntax if using a windows laptop or PC command shell is:
route add iLO_IP_address mask 255.255.255.255 OA_service_IP_address
After the route to an iLO has been added to the laptop or PC, the iLO can be accessed from the OA GUI or

directly using SSH.
The active Onboard Administrator does not support routing from the service port to an interconnect module

management processor. However if the interconnect module supports the serial connection to the OA, then

the OA CLI “connect interconnect” command can be used to connect to an interconnect module.
The service port connection is only intended as a temporary Ethernet connection to the enclosure private
network to eliminate disconnecting the management port from the external management network for access

to the Onboard Administrator during a maintenance event.