HP Onboard Administrator User Manual

Page 9

Advertising
background image

Introduction 9

server iLO, interconnect

management processors such

as Virtual Connect which use
the Onboard

Administrator/iLO

management port

such as Virtual Connect

Manager to other VC modules

in the enclosure.

Administrator.

Information and health status
reporting for all blades,

interconnects, fans, power

supplies, Onboard
Administrators, and enclosure

through Onboard

Administrator's GUI or CLI,
alert mail, or SNMP

Yes. Complete control.

No information is available

from the Onboard
Administrator nor is any

out-of-band information

available from VCM or iLO on
any server.

Yes. Complete control,

including sustaining a failure
of either Onboard

Administrator.

Insight Display

Yes. Complete control.

No.

Yes. Complete control,
including sustaining a failure

of either Onboard

Administrator.

Enclosure DVD (requires
either c3000 DVD option,

external USB DVD drive, or
USB key)

Yes. Complete control.

No.

Yes. Complete control,
including sustaining a failure

of either Onboard

Administrator.

Enclosure KVM (requires

c3000 KVM option or
Onboard Administrator

module with VGA connector)

Yes. Complete control.

No.

Yes. Complete control. For the

HP c3000 Enclosure, requires

both c3000 KVM option and
redundant Onboard

Administrator option. For the

HP c7000 Enclosure, requires

two of the newer Onboard
Administrator modules with

VGA connector.

Stored Onboard Administrator settings and module replacement
Enclosure model

Single Onboard

Administrator in enclosure

Redundant Onboard

Administrator (same
replacement type

installed)

1

Redundant Onboard

Administrator (different
replacement type

installed)

1

c3000

All enclosure settings are lost
when a single module is

removed and must be restored

manually using Insight Display
and USB key, GUI, or CLI.

All enclosure settings are
retained on the remaining

module and those settings are

synchronized to the replaced
module if the firmware

versions match.

2

When changing from the
non-redundant c3000

Onboard Administrator to

redundant Onboard
Administrator with DDR2, the

enclosure settings must be

restored manually using

Insight Display and USB key,
GUI, or CLI.

c7000

All enclosure settings are lost

when a single module is
removed and must be restored

manually using Insight Display

and USB key, GUI, or CLI.

All enclosure settings are

retained on the remaining
module and those settings are

synchronized to the replaced

module if the firmware
versions match.

2

All enclosure settings are

retained on the remaining
module and those settings are

synchronized to the replaced

module if the firmware
versions match.

2

1

Removing a redundant Onboard Administrator module immediately results in the remaining module becoming the

Active Onboard Administrator.