HP Onboard Administrator User Manual

Page 33

Advertising
background image

HP BladeSystem Insight Display 33

TIP:

Select the ? icon to access detailed help information about each setting or topic.

TIP:

Within any menu option, navigate the cursor to What is This, and press the OK button to

view additional information about each setting, option, or alert.

4.

When all settings on the Enclosure Settings menu are accurate, move the cursor to Accept All, and press
OK to accept the current settings.
You can change the following options in the Enclosure Settings screen:
Power Mode—The default setting is AC Redundant. The following selections are valid:

o

AC Redundant

o

Power Supply Redundant

o

None

Power Limit—The default setting is Not Set. You can change the limit by increments of 50 Watts.

CAUTION:

When calculating the Power Limit Watts AC value, derate the circuit to 80% of the

maximum to prevent tripping the circuit breaker (United States only).

CAUTION:

If your facility cannot support the calculated peak Watts AC, set the Power Watts AC

value to match the capability of your facility.

Dynamic Power—The default setting is Disabled. The following selections are valid:

o

Enabled—Some power supplies can be placed on standby to automatically increase overall
enclosure power subsystem efficiency.

o

Disabled—All power supplies share the load. The power subsystem efficiency varies based on load.

NOTE:

Dynamic Power is supported with all c3000 power supplies. It supports c7000 power

supplies only if operating with high-line input voltage (such as 220V AC). It is not supported with
c7000 -48V DC power supplies.

OA1 IP Addr—The default setting is DHCP. If no IP address is received, the IP address is 0.0.0.0. The
IP address, mask, and gateway are set within this option.
OA2 IP Addr—If this module is present, the default setting is DHCP. If no IP address is received, the IP
address is 0.0.0.0. If only one Onboard Administrator module is installed, the screen displays "Not

Present."