3. SAFETY PRECAUTIONS
The following general safety precautions supplement the
specific WARNINGs, CAUTIONs and NOTEs that appear
elsewhere in this manual.

3.1 Laser Radiation. The AN/PEQ-2A employs invisible
laser radiation in the form of Infrared (IR) Aim and
Illumination Lasers. Nominal Ocular Hazard Distances
(NOHD) for safe operation are listed in Table i-1. Exposure
to the AN/PEQ-2A’s IR lasers inside these NOHDs can
cause irreversible damage to the human eye.

Table i-1 Nominal Ocular Hazard Distances for Safe

Operation (NOHD)

Laser/Mode Safety

Class

NOHD

w/o

1

NOHD

mag

2

OD

3

Unaided

OD

4

Aided

Infrared (IR)
Aim Low

1 0 0 - -

Infrared (IR)
Illuminator
Laser Low

3R 11 85

0.30

0.54

Infrared (IR)
Aim Laser
High

3B 218

1300

1.58 1.45

Infrared (IR)
Illuminator
Laser High

3B 55 331

1.41

1.65

1

Nominal Ocular Hazard Distance without magnifying optics (in meters)

2

Nominal Ocular Hazard Distance with 7x magnifying optics (in meters)

3

Necessary Optical Density (OD) at 10cm

4

Necessary Optical Density (OD) at 2m




Advertising